Rupture of Refinery Heat Exchanger

12:23 PM Tue Mar 18, 2014 -- Anonymous (not verified)

A petroleum refinery experienced a catastrophic rupture at one bank of three heat exchangers in a catalytic reformer/naphtha hydrotreater unit because of high temperature hydrogen attack (HTHA). Hydrogen and naphtha at more than 500F were released from the ruptured heat exchanger and ignited, causing an explosion and an intense fire burned for more than three hours.

Hydrogen Fire from Valve Packing During Maintenance Shutdown at Chemical Manufacturing Plant

12:23 PM Thu Oct 31, 2013 -- Anonymous (not verified)

A chemical plant experienced a valve failure during a planned shutdown for maintenance that caused hydrogen to leak from a valve and catch fire. Four chemical reactor chambers in series were being emptied of liquid using hydrogen gas as part of a maintenance procedure. Two heater valves were opened allowing 3000 psi hydrogen to flow in reverse direction to purge the reactor system for approximately 25 minutes. At completion of the purging process, a "light" thud was heard as the reactor empty-out valves are being closed.

Pressure Relief Device Fails at Fueling Station

12:23 PM Tue Jun 25, 2013 -- Anonymous (not verified)

A pressure relief device (PRD) valve failed on a high-pressure storage tube at a hydrogen fueling station, causing the release of approximately 300 kilograms of hydrogen gas. The gas ignited at the exit of the vent pipe and burned for 2-1/2 hours until technicians were permitted by the local fire department to enter the station and stop the flow of gas. During this incident the fire department evacuated nearby businesses and an elementary school, closed adjacent streets, and ordered a high school to shelter in place.

Industrial Hydrogen Purifier Explosion

12:23 PM Tue Aug 21, 2012 -- Anonymous (not verified)

An explosion occurred in a hydrogen liquefier/purifier commissioned in 1987, after it had previously operated safely for many years. The explosion took place in the nitrogen cold box section of the hydrogen liquefaction process in an activated carbon cold adsorber vessel. Process records showed that the explosion occurred at the beginning of the regeneration phase of the activated carbon adsorber. When the explosion took place, the outlet temperature of the activated carbon bed was still at -190C.

Lithium Aluminum Hydride Laboratory Fire

12:23 PM Tue Apr 10, 2012 -- Anonymous (not verified)

A university researcher reported that a fire resulted when he scraped lithium aluminum hydride (LiAlH4) out of the glass jar in which it was contained (see attached photo). The jar had been in the laboratory since 2005 (about 6 years), so the LiAlH4 was old. The researcher was using a dry metal spatula to scrape the LiAlH4 out of the jar. A quick review of the manufacturer's Material Safety Data Sheet (MSDS) for LiAlH4 informed the researcher of its moisture sensitivity, but there was no indication of friction causing a fire.

Ignition of Syngas Leak from Ammonia Production Plant

12:23 PM Fri Mar 30, 2012 -- Anonymous (not verified)

During restart of an ammonia production plant, syngas (50% hydrogen mixed with methane, ammonia, and nitrogen) leaking from a flange directly downstream of the synthesis reactor ignited. The plant had been shut down for about 90 minutes due to a technical problem. Alerted by the plant fire alarm, the operator activated the emergency shutdown, which isolated and depressurized the synthesis loop. Steam was sprayed onto the leak site to dampen the fire, which was brought under control 55 minutes later.

Hydrogen Explosion in a Concrete Block Production Plant

12:23 PM Fri Mar 30, 2012 -- Anonymous (not verified)

A trained operator was blending water, sand, anhydrite, lime, cement, pulverized fly ash, and powdered aluminum in a mixing chamber to produce material for making concrete building blocks. In the blending process, sand and water are mixed to form a slurry, and then the powders are dispensed automatically into the mix by a computer-controlled system. Finally, a slurry of glycol-coated aluminum powder is added in the last few seconds before the mix is discharged into a car, and then molds are filled from the car.

Hydrogen Leak Ignites and Explodes in an Ammonia Production Plant

12:23 PM Fri Mar 30, 2012 -- Anonymous (not verified)

A hydrogen leak at the flange of a 6-inch synthesis turbocharger valve in an ammonia production plant ignited and exploded. Hydrogen detectors and the fire alarm alerted the control room, which immediately shut down the plant, and the fire was then extinguished rapidly. There were no injuries caused by the accident, since the operator heard a wheezing sound and was able to run away just before the explosion occurred. The leaking gas was composed of 70% hydrogen at a flow rate of 15,000 cubic meters per hour.

H2/N2 Mixture Incorrectly Connected to Infrared Spectrometer

12:23 PM Wed Oct 12, 2011 -- Anonymous (not verified)

A gas mixture cylinder was connected to a Fourier Transform Infrared (FTIR) Spectrometer to purge residual carbon dioxide and water vapor. A staff member was preparing to use the FTIR instrument. Prior to use of the instrument, it must be purged with dry nitrogen to remove residual carbon dioxide and water vapor. When the gas mixture reached the instrument's globar (resistively heated ceramic) heat source, a localized explosion occurred. No injuries resulted from the explosion but the spectrometer housing was heavily damaged.