Skip to main content

HIAD Nature of the Consequences: Explosion


The fire started 3 hours after being shut down. The unit was shut down and the fire extinguished.The oven contained only gaseous products and mainly hydrogen.
The event occurred while starting a new production cycle. The production supervisor issued specific instruction on a new production cycle to a technician. The technician did not follow them in the…
The event occurred during the decommissioning of a nuclear power plant. It involved a tank containing 100 kg of residual sodium from the decommissioned experimental nuclear reactor which was using…
At about 3:15 p.m. on Dec. 3 2003, personnel in the Expended Core Facility at the Naval Reactors Facility heard a loud, unexpected noise. Upon investigation, personnel found an irradiated material…
The event occurred in a silicon hydride (SiH) emulsion production process inside an enclosed production building. The process generated a flammable gas cloud gas ignited, which later ignited causing…
The fire ignited roofing materials which had fallen down as the result of the explosion.The operator, who was outside the plant when the explosion occurred, pulled the emergency switch which shut…
The incident occurred in an electrostatic filtration unit. When flushing with air during the start-up phase of a sulphonation plant, an explosion occurred in the upper partof the electrostatic…
An explosion occurred in a electrolyzer cell, the vent blew up and caused a pipe rupture on the low pressure chlorine pipeline. The event occurred when two operators were improving the tightness of…
The explosion took place in the hydrogen gasometer. The bell in the gasometer was lifted 15-20 m straight up and cracked. The cover fell down on the pipe bridge besides the gasometer. The cylindrical…
The explosion occurred while starting up for the first time a hydrogenation reactor.The reactor was being commissioned, by performing tightness tests under hydrogen atmosphere at very high pressure.…
A tank receives, after a negative reactivity test with the bottom supernatant of the tank, 20 m of methyl hydro-dichloro-silane, then 24 m of a mixture of oil and tar (negative reactivity test) and…
The soldiers of the Royal Prussian Air Ship Division stored large amounts of hydrogen gas. They kept some 1000 cylinders in a shed. On 25 May 1894 about 400 of them burst without apparent reason.…
A fire and a series of explosions occurred on a petrochemical plant, causing damage to process vessels, containment walls and process utility piping. It is believed that lightning struck a two story…
The explosion occurred in a plant for the production of butter. It was due to the rupture of a hydrogen tank, during a sterilization process at high temperature (so-called UHT treatment). Two…
When filled with air, a tyre of a car suddenly exploded, and the car was burned out. The car illegally carried the hydrogen cylinders. Hydrogen leaked from the cylinders and was thought to be ignited…
The incident occurred in a pharmaceutical plant. A disk ruptured on the vent of a reactor and the reaction mixture was projected onto a frontage of the synthesis workshop. It caused a spill of 700 l…
(WARNING, UNCLEAR IF H2 WAS INVOLVED)The explosion occurred in a chemical reactor tank of a plant (SEVESO low level) manufacturing products for medical imaging. According to the investigation, the…
During chlorine-alkali electrolysis an accident occurred in which chlorine was released due to a chlorine-hydrogen explosion. The person charged with the control of the measurements was informed by…
A deflagration occurred during shutdown of a reactor used for ammonia synthesis. It was followed by a jet fire. The hydrogen leak was probably due first to the lower seals, followed by another leak…
In a chlorine electrolysis facility, a mixture of oxygen and hydrogen in one of the electrolyzer cells a short-circuit ignited causing a deflagration. The cover of the cell was a thin plastic film…