Skip to main content

HIAD Facility - Application: Nuclear Power Plant


The event occurred during the decommissioning of a nuclear power plant. It involved a tank containing 100 kg of residual sodium from the decommissioned experimental nuclear reactor which was using…
At about 3:15 p.m. on Dec. 3 2003, personnel in the Expended Core Facility at the Naval Reactors Facility heard a loud, unexpected noise. Upon investigation, personnel found an irradiated material…
The event occurred in the steam condensing line of the residual heat removal system the nuclear reactor. Radiolysis generated hydrogen and oxygen which then accumulated in high concentration in the…
A hydrogen explosion had ruptured a pipe in the core spray system at the Brunsbttel BWR in Germany. Although the control room instrumentation had at the time indicated a leak of radioactive steam,…
An hydrogen explosion occurred within the off-gas system, causing the stop of the sump pump; subsequently both trains of the standby gas treatment system were declared inoperable. The sump is part of…
A hydrogen explosion caused burns contaminated with radioactive dust to a member of the plant's maintenance crew. Three other workers escaped injury.The accident occurred in the basement of the…
This entry reports only the role of hydrogen in this nuclear accident. For a short description of the initial causes and the incident evolution, see at field pre-event summary and for a much more…
A hydrogen leak occurred on the a coolant pipe of an electrical generator located in the turbine building, at 200 m from the reactor. Because of the welding works ongoing at that moment on the pipe…
An in-tank explosion occurred in a gaseous waste decay tank while the plant was in cold shutdown. The gaseous hydrogen present in the tank formed a flammable mixture and ignited due to air…
The accident occurred in a disposal storage for contaminated waste, consisting in a 65-metre shaft flooded with seawater. At the origin of the explosion was the reaction with water of at least two…
Rockville, Maryland, on June 9th, the control panel door for the 32 hydrogen dryer blew off due to a small hydrogen explosion. No one was injured in the event, which occurred in the non-nuclear side…
A catastrophic failure of the low pressure turbine followed by fire and flooding severely damaged the generator. The main turbine automatically tripped due to an erroneous mechanical over speed…
Piping breakage at atomic power plant- Steam piping (inside diameter: 15 cm; thickness: 1.1 cm) of a heat exchanger for removing residual heat from a reactor was broken during the test of a high…
At a nuclear power plant, a fire occurred in the station's hydrogen storage facility while the plant was operating at 100% power. The fire was reported to the control room by a non-licensed operator…
A technical failure in the High-Pressure turbine blades caused high vibrations in lubricating oil pipes. Some pipes broke off and the oil leak caught fire from hot surfaces. Also the generator's…
A hydrogen skid was placed into service in a nuclear power plant, outside the controlled area. This skid, like seven others, was located in a gas cylinder storage facility. It was supplied by several…
The incident occurred in the turbine-generator hall of a nuclear power plant. Hydrogen leaked from the alternator and ignited.The hydrogen line was purged to stop the leak. The plant employees were…
On April 29, 1991, a nuclear Power Plant experienced a main generator hydrogen fire. Although a senior reactor operator (SRO) and auxiliary operators from another shift were available immediately,…
Hydrogen ignition during welding on a VSC-24 spent fuel cask Pursuant to 10 CFR 72.210 - fuel in an independent spent fuel storage installation at its Point Beach Nuclear Power Plant. The inspection…
The explosion occurred while maintenance personnel were grinding a high-pressure injection (HPI) pipe, which had been recently cut at approximately 18 inches from the nozzle connecting the HPI pipe…