Skip to main content

HIAD Facility - Location Type: Confined


The explosion occurred during repair work on a boiler. A technician had previously descaled the device using hydrochloric acid, after which he performed the neutralisation step with soda and drained…
At 11:15 pm, an explosion followed by fire occurred in the vicinity of the measurement transformer on an isolated 90,000 V electrical oil transformer at a plant manufacturing technical polymers.…
A mixture of hydrocarbon and hydrogen leaks from hydrogenation unit of a refinery. The cloud explodes. The leak was caused due to corrosion of a carbon steel pipe at a bend, which was one eighth…
An explosion occurred involving a Microbiological Anaerobic Chamber of approximately 2 m3 capacity, containing an explosive mixture of hydrogen and air. A fire followed the explosion, but was rapidly…
This entry reports only the role of hydrogen in this nuclear accident. For a short description of the initial causes and the incident evolution, see at field pre-event summary and for a much more…
A large explosion happened in the contractor amenities area. The explosion was thought to be caused by an explosive mixture of air and hydrogen which existed in the pipes. The force of the explosions…
The reduction stage of the powder production process of a chemical plant had been shut down, and the buffer tank of the line had been drained on the preceding day. After the shutdown, the batch to be…
A gas release occurred in the building for the recirculation of processes gas. The gas was a mixture of hydrogen and nitrogen. It occurred at the outlet valve, during works aiming to replace it. This…
An explosion occurred at testing equipment of a fuel-feeding system for a space rocket engine. According to the original source of this event, now lost, the test envisaged a 42 MPa high-pressure…
Workers were performing demolition on a disused furnace. While removing a 10 inch valve from a pipe used to supply coke gas fuel to the furnace, flammable liquid was unexpectedly released and ignited…
A deflagration occurred inside the tank at the start of grinding operations. The tank had contained sulfuric acid. All preparatory procedures had been properly carried out: neutralisation of…
The incident occurred in a facility chrome-plating metals. At the time of the event, a metal roller was being chrome-plated. A short circuit occurred due to a defective contacting (contact rails) on…
An explosion occurred around noon while conducting hot work (with a disc saw) on a 320-m fixed-roof tank at a pharmaceutical plant employing 240 personnel. The tank belongs to a waste treatment…
The explosion occurred in the ammonia/hydrogen separator of the ammonia reactor due to metallurgical problem.
The explosion was caused by the ignition of hydrogen during reaction with sodium metal. The Chemistry Department routinely dried solvents using metallic sodium. This leaves an excess of sodium metal…
Hydrogen was accidentally produced inside the sealed container containing a used battery. The gas, along 6 days deformed the container. Firefighters equipped with breathing apparatus open the…
The explosion occurred in a copper electroplating plant test furnace when starting the operation of copper plating. EVENT DETAILS A tinned copper pipe had been placed inside another copper pipe and…
In the acid treatment room of a Seveso low-threshold hazardous waste treatment centre, an explosion occurred on a 250 m concrete tank containing acid sludge being neutralized. The explosion occurred…
The explosion occurred in an incinerator for non-industrial wastes, during inspection and repair works. These were due to a large quantity of aluminum which produced a solid lump of ash. The…
In a chlorine manufacturing unit, an explosion occurs in the room of the electrolysis cells. The accident occurs during the start-up phase of the unit, it is due to the presence of hydrogen in the…