The event occurred during the disconnection of the hydrogen compressor for maintenance.Two deaths and three injured workers were the consequences. The cause(s) of the event are unknown.
The accident occurred during the maintenance of a sulfuric acid storage tank in an industry for the fertilizers production. The maintenance works consisted in cutting operations (to remove some…
Leak from faulty hydrogen seal ignited by short circuit between inboard slip ring and outboard slip ring radial lead connection. Hydrogen flame caused damage to brush gear assembly and inboard slip…
Hydrogen gas leaking from drain pipes in a hydrodesulfurization plant: There was a hydrodesulfurisation plant which had a recycle hydrogen compressor fitted with a suction rectifier. Hydrogen gas…
During repairs of a heat exchanger in a benzene plant, a mixed gas (methane and hydrogen) contained in the cold box attached to the exchanger leaked and caught fire from a welding spark. The…
A ruptured hydrogen line caught fire at a commercial gas plant.
Fire due to hydrogen gas leakage from a cadre falling in transportation.
Leaking hydrogen ignited a fire that burned several hours at an oil refinery.
The fire started as a result of an explosion in the process section of a refinery. An open structure of steelwork protected with reinforced concrete housed the usual furnaces, reactors, heat…
The explosion occurred at a hydrogen fuel plant mainly serving hydrogen forklift fleets. The explosion damaged several nearby homes and could be felt nearly 10 miles away.Police and firefighters…
Unit tripped on-load due to serious fire between alternator and number 12 bearing. Fire extinguished by fire brigade. No injuries. Serious site damage was sustained to in CT chamber and alternator…
The Unit for Catalysed Removal of Carbon Dioxide (Catacarb) leaked and hydrogen fire at the hydrocracking unit. The fire lasted approximately 10 minutes. Localized corrosion caused a pipe to fail and…
Chlorine was released in the liquefaction unit of a chlorine electrolysis plant, due to the rupture of a pipe. During the re-start phase of an electrolysis workshop in a chemical plant, chlorine (…
The fire started in a electrolysis cell. The fire originated from a hydrogen leak in the hydrogen over pressure control system of the cell and an unidentified ignition source. The ARIA report (sew…
At a refinery, a leakage and fire occurred during usual operation at a medium-pressure hydrocracker for the desulfurization and decomposition of heavy gas oil. Gas of high-temperature and high-…
A fire occurred in a hydrogen and catalyst loading lines of heavy oil unit. The most likely cause was that a hydrogen purge pipeline failure allowing hydrogen to escape. This mixed with hot oil…
A fire occurred at a refinery hydrocracker plant involving a gauge glass and hydrogen gas oil.
When waste alkali solution was taken out of dumper trucks into a waste liquid storage tank, a reaction occurred in the tank. As a result, the solution in the tank foamed over it, and reached an…
Hydrogen line at ammonia plant sprang a leak which ignited. Fire put out immediately causing no damage.
A fire broke out on a heat exchanger in a hydrocarbons plant. The cause of the fire was leakage of hydrogen.