Skip to main content

HIAD Nature Event - Flame Type: Jet flame


While filling a 9 litre gas cylinder with pressurised hydrogen in the hydrogen storage area, a blast occurred which destroyed the low pressure gauge, followed by a jet fire which damaged the…
A fire broke out affecting the heavy fuel purification plant of the refinery.The incident could have originated by the failure of one of the following plant components:- pipes leading to the pressure…
The fire, 1 m high fire occurred in a pipe at the inlet of the hydrodesulfurisation unit of a refinery. The fire was caused by the leak of the pipe content, hydrogen and diesel fuel. According to the…
A 2-inch line carrying hydrogen gas at approximately 2,800 psi (approximately 19.3 MPa) failed at a weld, resulting in a high pressure hydrogen fire. The fire resulted in flame impingement on the…
The fire occurred after a hydrogen released from a venting valve opened for inspection. The hydrogen was at 300 bar and 300C centigrade. The hydrogen ignited probably spontaneously and killed 4…
The hydrogen jet fire a pipe have been detected by a night operator which was making rounds in a solvent production unit. The unit's emergency response team managed the fire in minutes. Operators…
The fire occurred on a flange of a hydrogen supply line to a desulfurization reactor unit of diesel, which leaked and ignited (30 cm flame) The leak was stopped by isolating the part of line…
A hot oil line (8-inch) in the hydro-desulfurisation (HDS) unit failed due to fatigue cracking. Hot oil at 50 bar and 343C sprayed across the roadway into the hydrogen units where ignition occurred.…
A hydrogen fuel tank release caused a fire at an AC Transit fuel station, prompting authorities to, as a precaution, evacuate several businesses and a high school and to close a number of…
A hydrogen jet fire occurred on a 25m3 tank while transferring a catalyst to a buffer tank. The constabulary created an area of safety around the plant while the staff extinguishes the fire by…
A hose of a hydrogen tanker parked in at a specialised company ruptured. The released hydrogen ignited and exploded, followed by a fire probably fed by the continuously leaking hydrogen. The local…
This resulted in the destruction of the building where the explosion occurred and claimed the lives of two people. The triggering event was a blowing out of a gasket in a water pump situated in a 100…
The event occurred in a university research building dedicated to the study of the take-off of space launchers . An operator gave the alarm during the hydrogen pressure pre-setting phase. he had seen…
A pressure relief device (frangible burst disk) on one of a hydrogen delivery tube trailer`s 26 tubes failed prematurely and released hydrogen while filling a hydrogen storage tank at a government…
An isomerization unit of a refinery was affected. The release was caused by the mechanical failure of one of the two compressors working in parallel at a pressure of 20 bars, conveying the gas…
A tractor - semitrailer with horizontally mounted cylinders filled with compressed hydrogen struck a northbound pickup truck that had veered in front of it.The tractor-semitrailer then went out of…
The leak occurred at the ammonia reactor after a technical shutdown of 4 days. When the production was resumed and the syngas compressor restarted 14 hours later, a jet-fire occurred. The Internal…
A 24" pipe carrying synthesis gas (Hydrogen = 43.5%, Nitrogen = 14.08%, Methane = 0.2%, Carbon Dioxide = 12.3%, Water = 29.3% by volume) ruptured. About 60 kg of hydrogen contained in the gas…