Skip to main content

HIAD Quality Indicator: 2


FCEV road collision. Details unknown.
Hydrogen gas leaking from drain pipes in a hydrodesulfurization plant: There was a hydrodesulfurisation plant which had a recycle hydrogen compressor fitted with a suction rectifier. Hydrogen gas…
During repairs of a heat exchanger in a benzene plant, a mixed gas (methane and hydrogen) contained in the cold box attached to the exchanger leaked and caught fire from a welding spark. The…
A ruptured hydrogen line caught fire at a commercial gas plant.
A fire in a leaking hydrogen unit at a 220,000-barrel oil sands plant temporarily cut production nearly 80 percent.
A fire in a metallurgical plant (classified Seveso)The fire initiated in a acid treatment reactor of a workshop handling cementation of indium . Under normal conditions, the reaction of the process…
Fire due to hydrogen gas leakage from a cadre falling in transportation.
Leaking hydrogen ignited a fire that burned several hours at an oil refinery.
An operator had just replaced the ignition port cover on a hydrochloric acid plant burner. Normal start-up was continued by closing the drain valve in the product run off line and opening the…
The fire started as a result of an explosion in the process section of a refinery. An open structure of steelwork protected with reinforced concrete housed the usual furnaces, reactors, heat…
The explosion and fire happened in a diesel hydro-treatment unit used to desulfurise raw diesel be means of hydrogen.The facility was expected to begin full commercial operations later in 2020.
The explosion occurred at a hydrogen fuel plant mainly serving hydrogen forklift fleets. The explosion damaged several nearby homes and could be felt nearly 10 miles away.Police and firefighters…
Unit tripped on-load due to serious fire between alternator and number 12 bearing. Fire extinguished by fire brigade. No injuries. Serious site damage was sustained to in CT chamber and alternator…
The Unit for Catalysed Removal of Carbon Dioxide (Catacarb) leaked and hydrogen fire at the hydrocracking unit. The fire lasted approximately 10 minutes. Localized corrosion caused a pipe to fail and…
Two successive fires broke out in an interval of few minutes in four cells in the electrolysis room of a chlorine production plant. The technicians brought the fire under control using the fire-…
At a refinery, a leakage and fire occurred during usual operation at a medium-pressure hydrocracker for the desulfurization and decomposition of heavy gas oil. Gas of high-temperature and high-…
A fire occurred at a refinery hydrocracker plant involving a gauge glass and hydrogen gas oil.
A hydrogen leak occurred from a low temperature valve on an acetic acid plant. The leak ignited and the resulting fire burned for about an hour. There was considerable media attention, particularly…
Hydrogen line at ammonia plant sprang a leak which ignited. Fire put out immediately causing no damage.
A fire broke out on a heat exchanger in a hydrocarbons plant. The cause of the fire was leakage of hydrogen.