Skip to main content

HIAD Specific Application Supply Chain Stage: Hydrogen Transport


A lorry crashed into a hydrogen tube trailer with considerable speed on the highway A1 near Cologne. The lorry driver was killed. Gas escaped from tubes and valves of three of the nine tanks and was…
A pressure relief device (frangible burst disk) on one of a hydrogen delivery tube trailer`s 26 tubes failed prematurely and released hydrogen while filling a hydrogen storage tank at a government…
The whole content of the rail tanker, that is 42,000 l (about 2600 kg) of liquid hydrogen, was entirely lost over a period of seven hours via the venting line of a tank. The accident occurred at a…
The tanker truck was carrying nearly 13,000 gallons of liquid hydrogen. it hit the base of a light pole in the parking lot of a local grocery store as the driver was attempting to turn around.…
Motorway accident which involved a large quantity of vehicles and a gaseous tube trailer which transported gas hydrogen in pressure. Some cars were burning under the back part of the gaseous tube…
[NOTE: The system involved in this neear miss are not completely clear]The system involved appears to consist in an electrolyzer, a compressor and high pressure tanks, used to refuel hydrogen buses.…
An oil leak in a compressor was identified in the end of Aug 2015 by a technician performing regular maintenance on the compressor. The oil leak had caused a contamination of the entire system from…
A hydrogen pipe burst at a semiconductor plant injuring 1 person
A tractor - semitrailer with horizontally mounted cylinders filled with compressed hydrogen struck a northbound pickup truck that had veered in front of it.The tractor-semitrailer then went out of…
A leak occurred in a vehicle carrying 218 cylinders of hydrogen. The contents of 28 cylinders, 90 m of hydrogen, escaped. A security perimeter was set up with stop of the road and rail traffic.
A leak occurs on a hydrogen gas transport at a flange of 9 cylinders of 80 m. The producer of these cylinders decides to let it leak. No consequences to report.
A truck-trailer carrying compressed hydrogen cylinders stopped on an autobahn and reported a hydrogen leaking from the cylinders. The highway was immediately closed in both directions. When the fire…
During maintenance work on a gas pipeline carrying hydrogen , a worker hears a leak at about at a bridge. The operator measures an concentration of 3% of the low flammability limit at few…
Malfunctioning of the non-return valve of the hydrogen compressor has caused the pressure between the hydrogen bottle and the compressor to rise to the maximum allowed pressure of 275 barg. As a…
A hydrogen leak took place on a trailer carrying compressed hydrogen, located inside the fenced perimeter of a hydrogen station. According to the company managing the hydrogen delivery and refuelling…
A hydrogen feed line ruptured without igniting at an oil refinery.
A leak of 700 l of gaseous hydrogen was detected around on a connection of a rack of cylinders on a trailer truck, in aircraft plant (classified Seveso, lower tier).
Gas leakage from a hydrogen cylinders pallet in transit.
The release occurred after the collision between a truck containing liquid hydrogen and a truck containing manganese dioxide on a highway.Due to the release, the traffic was interrupted for 4 hours…
A leak occurred on the safety valve of a train wagon transporting liquid hydrogen wagon. The train was composed of 10 wagons. The train was stopped on the railway several hours to allow…