The accident took place in a tank-type pressurised separator on the synthesis gas line of an ammonia production plant. The pressurised separator operates at nominal values of 25 bar and 5C. It…
The fire was in a polyamide production chemical plant classified SEVESODuring maintenance of an isolated unit producing a polyamide monomer (LACTAME), a fire developed on the ground floor of the unit…
An explosion occurred in the hydrogen washing tower of a chlorate plant caused by the breaking of the rupture diaphragms on the tower cover. The discharged hydrogen ignited, causing a minor leakage…
While filling a 9 litre gas cylinder with pressurised hydrogen in the hydrogen storage area, a blast occurred which destroyed the low pressure gauge, followed by a jet fire which damaged the…
A man was burned when a fire broke out as a hydrogen cylinder was being changed in a governmental research centre. It was reported that the fire was started by a spark from a wrench. The sprinkler…
The event took place in the on one out of the seven reactors for ammonia synthesis. The day of the accident, preparation works for the decennial pneumatic test (previous pneumatic test was carried…
The hydrogen buffer tanks that exploded were part of an experimental facility experimenting generation of renewable hydrogen from a water electrolyzer coupled to solar panels.The three hydrogen tanks…
An over-dosage of natron lye in a silicon dust suspension container raised the ph-value up to 11, producing large amounts of hydrogen in a short time. The hydrogen caused an extreme pressure increase…
The explosion occurred when a spark from welding equipment ignited flammable vapours from a 415,000-gallon (ca. 1.5 million of litres) sulfuric acid storage tank at the refinery.The investigation…
The event early on a Saturday morning, when the plant was thus practically empty. Nevertheless, the chronology of the accident can be reconstructed from the testimonies of the few operators who were…
The fire broke out in the acid etching tank of the ferric chloride manufacturing unit of a SEVESO-classified chemical plant. In this tank, the attack reaction of the iron metal with hydrochloric acid…
Due to unsealing of flange connection in a heat exchanger, hydrogen leaked and ignited. At 20 m height, under pressure of 0,25 MPa.
A fire was sparked by a hydrogen leak at a Goodrich plant around 9:50 a.m. Friday, safety officials said. "Apparently the hydrogen caused a fire when it hit the air," said Chief Alex Rodriguez of the…
The event occurred in a university research building dedicated to the study of the take-off of space launchers . An operator gave the alarm during the hydrogen pressure pre-setting phase. he had seen…
An isomerization unit of a refinery was affected. The release was caused by the mechanical failure of one of the two compressors working in parallel at a pressure of 20 bars, conveying the gas…
The vessel affected by the incident was a gas storage used for the desulfurisation process. The desulfurization gas had high hydrogen content. The vessels had cracks in the upper transverse fillet…
The fire developed on one of two naphtha crackers The rupture of the reactor made that the hydrogen, petroleum products and the pyrophoric catalyst came outside the reactor. The mixture immediately…
The event affected the hydrocracker unit. A sudden release into a cracker compressor flare header destroyed a safety relief valve and damaged a sight glass on a liquid collection pot. As a…
Fire caused by leakage from tank. Gaseous hydrogen release in generator caused by turbine vibrations